Operational specification
Measuring range:
-50°C to +400°C
Resolution:
0.1°C
Accuracy:
0.5°C + 0.005 x t
Measuring Frequency*:
PT100 HT Magnet: Every 3 sec
PT100 HT Average Magnet: Every 10 sec
Report Frequency*:
PT100 HT Magnet: Reports every 2 min. Or immediately if trigger for critical data transmission is reached, see below
PT100 HT Average Magnet: Reports every 10 min. Or immediately if trigger for critical data transmission is reached, see below
Reported value:
PT100 HT Magnet: Reports last reading
PT100 HT Average Magnet: Reports average of 12 last readings
Trigger for Critical Data Transmission*:
PT100 HT Magnet: 2°C change in measurement
PT100 HT Average Magnet: 10°C change in measurement
Electronics Operating Environment:
Ambient temperature: -40 – 85 °C
Relative humidity: 0-100%
Altitude: < 2000m above sea level
Pollution degree: 4
IP Grade:
IP 67, wet conditions, indoor use
Radio Frequency:
863-870 MHz / 902-928 MHz
Battery Type:
Li-SOCl2, 3.6V
Expected Operating Time**:
Up to 10 years
* Adjustable on request
** Depends on measurement frequency, amount of critical data transmissions and ambient temperature
Physical specification
Materials:
Sensor: POLYblend 65 FS / TPU
PT100 probe: 316 Stainless Steel / Magnet
Connection Type:
Glass fibre wire
Process Connection:
Magnet
Dimensions LxWxH:
Sensor: 37x23x14mm
Magnet: 40x25x28mm
Regulatory
Certifications:
CE marking
UK CA
FCC
Industry Canada
Directives/Standard:
IEC 61010-1:2010
FCC Part 15C
RED 2014/53/EU Radio
Equipment Regulations 2017